What the opinion tells you
Under TREC rule 535.228(a), every Texas inspector must render a written opinion as to the performance of the foundation. It is one of the few places where the standards require the inspector to state a conclusion in words rather than simply check a box, and it is often the sentence a buyer reads most closely.
The opinion is a professional judgment about whether the foundation is doing its job, formed from what the inspector could see. Reports commonly phrase it along the lines of the foundation appearing to perform as intended, or showing signs of adverse performance, followed by the observations that support it. The wording is the inspector's; the duty to give an opinion is the rule's.
The indicators behind the opinion
The rule requires the inspector to report generally the present and visible indications used to form an opinion of adverse performance. It lists examples:
- binding, out-of-square or non-latching doors;
- framing or frieze board separations;
- sloping floors;
- window, wall, floor or ceiling cracks or separations;
- rotating, buckling, cracking or deflecting masonry cladding.
The inspector must also report the type of foundation and, where there is one, the vantage point from which the crawl space was inspected.
The rule says the inspector is not required to provide an exhaustive list of indicators of possible adverse performance. The list in the report is the evidence the inspector relied on, not a catalog of every crack in the house.
What is reported as Deficient
Separately from the opinion, the rule lists foundation conditions to report as Deficient: deteriorated materials; deficiencies in foundation components such as beams, joists, bridging, blocking, piers, posts, pilings, columns, sills or subfloor; deficiencies in retaining walls related to foundation performance; exposed or damaged reinforcement; and crawl space ventilation and drainage deficiencies.
That means a report can say the foundation appears to be performing and still mark a Deficient item under it, for example exposed reinforcement at the edge of a slab. The opinion and the Deficient box answer different questions.
What the opinion is not
It is not an engineering evaluation. The inspection is a limited visual survey, and the general limitations say inspectors are not required to determine the cause of a condition or anticipate future performance. A structural engineer evaluating a foundation may take elevation measurements, review the history of the house and examine more than a visual inspection can.
It is not a measurement. The standards do not require the inspector to take floor elevations. An opinion that a floor slopes is an observation, not a survey.
It is not a prediction. The opinion describes performance at the time of the inspection. Foundations on expansive clay soils, common in much of Texas, can move with seasonal moisture changes.
It does not cover retaining walls unrelated to the foundation. The rule says those are outside the inspection.
Common mistakes
Reading only the opinion and skipping the indicators. The listed observations are what make the opinion checkable. An opinion of adverse performance supported by one sticking door reads differently from one supported by sloping floors and cracked brick.
Treating "appears to be performing" as a guarantee. It is an opinion from visible evidence on one day. See appears to be.
Ignoring evidence of earlier foundation repair. Signs of previous repair are worth asking about even when the current opinion is favorable; the seller's disclosure and any repair warranty are the place to start.
What to do with it
If the opinion reports adverse performance, or the indicators listed concern you, the usual next step is an evaluation by a licensed professional engineer, arranged before the option period ends. Ask the seller for any engineering reports, repair contracts and transferable repair warranties for the foundation; a repair warranty that transfers on sale can matter as much as the repair itself. The guide to who does further evaluation explains how engineers and other professionals fit in.
Where the rules come from
The foundation requirements are in 22 TAC 535.228(a). The limits on determining causes and anticipating future conditions are in 22 TAC 535.227. TREC's continuing-education manuals give foundations their own module, including the difference between "report" and "report as Deficient"; see the 2021-2023 manual.