Overview
This category covers nine phrases in two groups. Four are things the standards require an inspector to report in words of the inspector's choosing: the written opinion on foundation performance, evidence of water penetration, evidence of previous repairs, and conditions that met the rules when the house was built but are reported as Deficient today. Five are the inspector's own qualifiers and recommendations: further evaluation, "appears to be", "at the time of the inspection", the limited visual survey and the end of useful life.
Required to be reported is not the same as Deficient
The most useful distinction in this category comes from TREC's own course manual: the requirement to report does not require an inspector to report as Deficient. For the roof, the inspector must report the type of covering, where it was viewed from, any evidence of water penetration and any evidence of previous repairs. None of those has to be marked Deficient. A stain on a ceiling that is dry, and a patch on a roof that appears sound, will often be reported in the comments with no Deficient box beside them. The point of reporting them is that a buyer can then ask the seller what happened.
Qualifiers are not boilerplate
A report full of "appears to be" and "at the time of the inspection" can read as defensive. Some of it is. But each qualifier is also a precise statement about the limits of a visual inspection. "Appears to be" marks a conclusion drawn from what could be seen. "At the time of the inspection" marks a condition that may change, such as a slow leak that only shows after rain. "Recommend further evaluation" marks a question the inspector is telling you to take to someone who can open the wall, run the test or carry the license. Reading past them is how a buyer ends up surprised by something the report actually mentioned.
Phrases TREC tells inspectors to avoid
TREC's 2023-2025 course manual lists things inspectors should not write: value scales such as rating items from one to ten, abbreviations, descriptions such as "very well maintained" or "excellent condition", statements that something does not appear to affect the structure, what the inspector would do if the house were theirs, guarantees, and the anticipated life span of a system or component. A report that uses them is not invalid, but those sentences carry less weight than they appear to, and a buyer should ask what each one rests on.
Why the wording varies
TREC fixes what an inspector must report but not how the sentences read. Report software supplies stock comment libraries, inspectors write their own, and both are edited for each house. The result is that the same finding can appear in one report as a short line and in another as a paragraph with a recommendation and a photograph. The phrase pages here explain the common forms so that a reader can recognize the same finding in different words.
It also explains why a reader should judge a comment by its content rather than its length. A long comment is not necessarily a serious one, and a short line can carry a hazard.
Reading a comment
TREC teaches that a good statement has two parts: the deficiency and where it is. Anything else is optional detail or a recommendation. When a comment is hard to follow, separate those parts. What did the inspector see? Where? Is there a box checked beside it? Is there a recommendation, and to whom? The answers usually make the comment's weight plain.
| Term | What it is | Family |
|---|---|---|
| The Foundation Performance Opinion | A finding | Things the rules require to be reported |
| Evidence of Water Penetration | A finding | Things the rules require to be reported |
| Evidence of Previous Repairs | A finding | Things the rules require to be reported |
| Conditions Not Required to Be Updated | A finding | Things the rules require to be reported |
| Recommend Further Evaluation | A gap in coverage | The inspector's own wording |
| Appears To Be | A qualifier | The inspector's own wording |
| At the Time of the Inspection | A qualifier | The inspector's own wording |
| Limited Visual Survey | A qualifier | The inspector's own wording |
| End of Useful Life | A qualifier | The inspector's own wording |