Inspection Report Reader logo — a house frame with a checkmark at its peakInspection Report ReaderWhat the words in a Texas inspection report mean
By family

The four families of inspection report terms

The boxes; the defined words; what the rules require an inspector to report; and the inspector's own wording. Where a word comes from decides how much weight it carries.

Overview

The seventeen terms on this site fall into four families, grouped by where each word comes from. The grouping is the fastest way to judge how much weight a word carries, because the source decides whether the meaning is fixed by the state or chosen by the inspector who wrote your report.

The first two families are fixed. The four boxes and the defined words mean the same thing in every Texas report, because a state rule says what they mean. The third family is fixed in substance but not in wording: the standards of practice require the inspector to report a foundation opinion, evidence of water penetration and evidence of previous repairs, and to report certain older-house conditions as Deficient, but they leave the sentences to the inspector. The fourth family is the inspector's own wording, which is where two reports on similar houses differ most.

Families also tell a reader where to look in a report. The four boxes sit in the left margin of every item. The defined words appear wherever the boxes are explained and in the preamble. The required reports appear in particular sections: the foundation opinion under Foundations, evidence of water penetration under roofs, attics, walls, ceilings, floors, doors and windows, and evidence of previous repairs under the roof covering. The inspector's own wording can appear anywhere, and is most concentrated in the comments on major systems.

Why the source matters

A word whose meaning is fixed by rule can be checked. If a report marks an item Deficient, the rule says what the inspector was asserting, and a buyer can hold the comment beneath it to that standard. A word the inspector chose can only be understood by asking the inspector. "Monitor", "typical for age" and "serviceable" appear in many reports, but no Texas rule defines them, and their weight depends on the person who wrote them.

The source also tells a buyer where to take a question. A question about what a box or a defined word means can be answered from the rule. A question about why a box was checked, or what a phrase in the comments was meant to convey, is a question for the inspector, and TREC's preamble invites it. A question about what to do about a finding is a question for the contract and, often, for a licensed trade, which is covered in the guide on who does further evaluation.

Using the families to sort a report

A practical way to read a report is to sort its sentences by family before deciding what to do. Box combinations tell you what was and was not examined. Defined words tell you what standard a finding was measured against. Required reports tell you what the inspector had to mention whether or not it was Deficient, which is often the most useful information for questions to the seller. The inspector's own wording tells you how confident the inspector was and what the inspector recommends you do next. Sorting this way separates findings from qualifiers and gaps, which is the purpose of the weight shown on every term page.

The weight scale and the families are independent. A box can be a gap (Not Inspected) or a finding (Deficient); the inspector's own wording can be a qualifier or a gap. Reading both together gives the fullest picture of a sentence.

The four families

The four boxes: 4 terms

Inspected, Not Inspected, Not Present and Deficient appear beside every item on the form. Their meanings come from TREC rule 535.223 and the form's instruction sheet, and they combine.

Words the rule defines: 4 terms

A hazard to life, limb or property, accessible, cosmetic and performance are defined in TREC rule 535.227. The boxes depend on them, and so do the silences in a report.

Things the rules require to be reported: 4 terms

The foundation opinion, evidence of water penetration, evidence of previous repairs and conditions not required to be updated are things the standards require an inspector to report, in words the inspector chooses.

The inspector's own wording: 5 terms

Further evaluation, appears to be, at the time of the inspection, the limited visual survey and the end of useful life are the inspector's own qualifiers and recommendations, and the place where reports differ most.

Words the rule defines

4 terms

Terms TREC rule 535.227 defines, which the boxes and the silences depend on.

Things the rules require to be reported

4 terms

Matters an inspector must report, in words the inspector chooses.

The inspector's own wording

5 terms

Qualifiers and recommendations no rule defines, where reports differ most.