Inspection Report Reader logo — a house frame with a checkmark at its peakInspection Report ReaderWhat the words in a Texas inspection report mean
Category one

The boxes and the words the rule defines

The boxes and definitions are the part of a Texas inspection report the state wrote. Every report on form REI 7-6 carries the same four boxes beside every item: Inspected, Not Inspected, Not Present and Deficient. Every one of them depends on words defined in TREC rule 535.227, and those definitions are the same in every report, whichever inspector wrote it.

Overview

That fixed meaning is the main thing a buyer can rely on. An inspector's comments vary in length, tone and care. The boxes do not. A checked Deficient box means the inspector judged that a condition adversely and materially affects the performance of a system or component, or constitutes a hazard to life, limb or property as the standards specify. A checked Not Inspected box means the inspector did not inspect that item, and the rule requires the reason to be stated in the report.

Why the definitions matter more than the boxes

Most misreadings of a Texas report come from reading a box in its everyday sense. Deficient sounds like a verdict of failure; in the rule it means the inspector reported one or more deficiencies, which can be as small as a missing cover plate. Inspected sounds like a clean bill of health; in the rule it means only that the item was examined, and an item can be checked Inspected and Deficient at once. Accessible sounds like a fact about the house; in the rule it is the inspector's reasonable judgment about whether something could be reached without hazard, moving belongings, special equipment or damage.

The definitions also explain the silences. A condition that is cosmetic, meaning it affects appearance only and not performance, operability or water penetration, is not required to be reported at all. Ordinary wear and tear is not required to be reported. Past repairs that appear effective and workmanlike are not required to be reported. A report that says nothing about worn carpet or faded paint is not incomplete; it is following the rule.

Combinations

The rule allows more than one box per item, and the combinations carry information. TREC's instruction sheet says Inspected and Deficient together mean the item was inspected and showed a deficiency. Inspected and Not Inspected together mean the item was only partly inspected, and the inspector must say which parts. Not Inspected and Deficient together mean the inspector did not inspect an item for a reason that itself meets the definition of a deficiency. The current rule requires the inspector to explain why whenever more than one box is checked. The guide to how the four boxes combine works through each.

The same words, every report

Because these meanings are fixed by rule, they are the one part of a report a buyer can compare directly between inspectors. Two reports on the same house may describe a crack in different words and at different length. If both mark the foundation item Deficient, both inspectors judged that a condition adversely and materially affects performance or is a hazard as the standards specify. If one marks it Inspected only and the other Deficient, the disagreement is about that judgment, and the comments should show why.

The fixed meanings also make a report easier to check against the rule. Each system rule, from 535.228 for structural systems to 535.233 for optional systems, lists what the inspector must report and what must be reported as Deficient. A buyer who wants to know whether a condition should have been marked can read the rule for that system. The term pages in this category quote the parts of those rules that matter most.

What this category does not include

It does not include the words an inspector writes in the comments, however often they appear. "Recommend further evaluation", "appears to be" and "at the time of the inspection" are common, and some are encouraged by TREC's own course manuals, but no rule defines them. They are in the comment phrases category, alongside the things the rules require an inspector to report in words of their own choosing.

What each inspection report term is, and which family it belongs to
TermWhat it isFamily
Inspected (I)A qualifierThe four boxes
Not Inspected (NI)A gap in coverageThe four boxes
Not Present (NP)A findingThe four boxes
Deficient (D)A findingThe four boxes
A Hazard to Life, Limb or PropertyA findingWords the rule defines
Accessible and InaccessibleA gap in coverageWords the rule defines
CosmeticA qualifierWords the rule defines
PerformanceA qualifierWords the rule defines
All 8

Boxes and definitions, by family


Words the rule defines

4 terms

Terms TREC rule 535.227 defines, which the boxes and the silences depend on.