Inspection Report Reader logo — a house frame with a checkmark at its peakInspection Report ReaderWhat the words in a Texas inspection report mean
The glossary

Every term in a Texas inspection report, and what it tells you

All 17 boxes, defined terms and stock phrases on this site, each with its weight stated up front: a finding, a qualifier, or a gap in what was checked.

Overview

This glossary lists all seventeen terms covered on this site, each with its weight stated before anything else: a finding, which records something the inspector observed; a qualifier, which limits what a finding claims; or a gap, which marks something the inspector did not check. Use the table if you already know the word you are looking for; browse by family below if you do not.

The weight matters because a Texas inspection report mixes the three on every page, and they read alike. A line under a roof item may say the inspector observed granule loss (a finding), that the roof was viewed from the ground because it was too steep to walk (a gap), and that the condition was noted at the time of the inspection (a qualifier). A buyer who reads all three as findings overestimates what was checked; a buyer who reads all three as boilerplate misses the one sentence that matters.

Where the words come from

Texas is unusual. Since February 1, 2022, every inspection a licensed inspector performs for a prospective buyer or seller of a substantially complete one-to-four family house must be reported on one state form, the Property Inspection Report Form REI 7-6, under Texas Real Estate Commission (TREC) rule 535.223. The form fixes the four boxes beside every item, the preamble pages at the front, and the order of the six sections from Structural Systems to Optional Systems. A separate rule, 535.227, defines the words the boxes depend on, including deficiency, accessible, cosmetic, inspect and performance. Other rules, 535.228 through 535.233, list what the inspector must report and what must be reported as Deficient for each system.

Everything else in the report is the inspector's own wording. Some of it is required in substance, such as the written opinion on foundation performance or the statement of why an item was not inspected, but the words are the inspector's choice. TREC's own continuing education manuals list phrases inspectors may consider, from "appears to be" and "limited" to "further evaluation" and "nearing end of useful life", and list things to avoid, including rating scales, abbreviations, guarantees and predictions of how long a component will last.

How to use a term page

Each term page opens with what the word tells you, followed by where it comes from, what the rule or the form says it means, what it does not tell you, the mistakes buyers most often make with it, and what to do about it before the option period ends. Every page names its sources, and those sources are the rules and forms themselves rather than summaries of them. Where a rule leaves a matter to the inspector's reasonable judgment, the page says so instead of inventing a standard.

A note on dates. REI 7-6, dated August 9, 2021, is the form in use as of November 2026. TREC proposed revisions to the standards of practice and the form in May 2026 and withdrew them in August 2026; its inspector committee sent a new draft to the Commission in October 2026. Any change would be proposed, published for public comment and adopted before taking effect. Pages on this site will be revised when that happens, and each page shows the date it was last reviewed.

What the glossary does not do

It does not interpret anyone's report. Two inspectors can look at the same crack and word it differently, and the meaning of a sentence in a particular report depends on the house, the photographs and the inspector's reasoning. The right person to explain a sentence is the inspector who wrote it, and the preamble of every Texas report invites the client to ask. This glossary helps you ask a better question.

What each inspection report term is, and which family it belongs to
TermWhat it isFamily
Inspected (I)A qualifierThe four boxes
Not Inspected (NI)A gap in coverageThe four boxes
Not Present (NP)A findingThe four boxes
Deficient (D)A findingThe four boxes
A Hazard to Life, Limb or PropertyA findingWords the rule defines
Accessible and InaccessibleA gap in coverageWords the rule defines
CosmeticA qualifierWords the rule defines
PerformanceA qualifierWords the rule defines
The Foundation Performance OpinionA findingThings the rules require to be reported
Evidence of Water PenetrationA findingThings the rules require to be reported
Evidence of Previous RepairsA findingThings the rules require to be reported
Conditions Not Required to Be UpdatedA findingThings the rules require to be reported
Recommend Further EvaluationA gap in coverageThe inspector's own wording
Appears To BeA qualifierThe inspector's own wording
At the Time of the InspectionA qualifierThe inspector's own wording
Limited Visual SurveyA qualifierThe inspector's own wording
End of Useful LifeA qualifierThe inspector's own wording
Browse

All 17 terms, by family


Words the rule defines

4 terms

Terms TREC rule 535.227 defines, which the boxes and the silences depend on.

Things the rules require to be reported

4 terms

Matters an inspector must report, in words the inspector chooses.

The inspector's own wording

5 terms

Qualifiers and recommendations no rule defines, where reports differ most.