Overview
This glossary lists all seventeen terms covered on this site, each with its weight stated before anything else: a finding, which records something the inspector observed; a qualifier, which limits what a finding claims; or a gap, which marks something the inspector did not check. Use the table if you already know the word you are looking for; browse by family below if you do not.
The weight matters because a Texas inspection report mixes the three on every page, and they read alike. A line under a roof item may say the inspector observed granule loss (a finding), that the roof was viewed from the ground because it was too steep to walk (a gap), and that the condition was noted at the time of the inspection (a qualifier). A buyer who reads all three as findings overestimates what was checked; a buyer who reads all three as boilerplate misses the one sentence that matters.
Where the words come from
Texas is unusual. Since February 1, 2022, every inspection a licensed inspector performs for a prospective buyer or seller of a substantially complete one-to-four family house must be reported on one state form, the Property Inspection Report Form REI 7-6, under Texas Real Estate Commission (TREC) rule 535.223. The form fixes the four boxes beside every item, the preamble pages at the front, and the order of the six sections from Structural Systems to Optional Systems. A separate rule, 535.227, defines the words the boxes depend on, including deficiency, accessible, cosmetic, inspect and performance. Other rules, 535.228 through 535.233, list what the inspector must report and what must be reported as Deficient for each system.
Everything else in the report is the inspector's own wording. Some of it is required in substance, such as the written opinion on foundation performance or the statement of why an item was not inspected, but the words are the inspector's choice. TREC's own continuing education manuals list phrases inspectors may consider, from "appears to be" and "limited" to "further evaluation" and "nearing end of useful life", and list things to avoid, including rating scales, abbreviations, guarantees and predictions of how long a component will last.
How to use a term page
Each term page opens with what the word tells you, followed by where it comes from, what the rule or the form says it means, what it does not tell you, the mistakes buyers most often make with it, and what to do about it before the option period ends. Every page names its sources, and those sources are the rules and forms themselves rather than summaries of them. Where a rule leaves a matter to the inspector's reasonable judgment, the page says so instead of inventing a standard.
A note on dates. REI 7-6, dated August 9, 2021, is the form in use as of November 2026. TREC proposed revisions to the standards of practice and the form in May 2026 and withdrew them in August 2026; its inspector committee sent a new draft to the Commission in October 2026. Any change would be proposed, published for public comment and adopted before taking effect. Pages on this site will be revised when that happens, and each page shows the date it was last reviewed.
What the glossary does not do
It does not interpret anyone's report. Two inspectors can look at the same crack and word it differently, and the meaning of a sentence in a particular report depends on the house, the photographs and the inspector's reasoning. The right person to explain a sentence is the inspector who wrote it, and the preamble of every Texas report invites the client to ask. This glossary helps you ask a better question.
| Term | What it is | Family |
|---|---|---|
| Inspected (I) | A qualifier | The four boxes |
| Not Inspected (NI) | A gap in coverage | The four boxes |
| Not Present (NP) | A finding | The four boxes |
| Deficient (D) | A finding | The four boxes |
| A Hazard to Life, Limb or Property | A finding | Words the rule defines |
| Accessible and Inaccessible | A gap in coverage | Words the rule defines |
| Cosmetic | A qualifier | Words the rule defines |
| Performance | A qualifier | Words the rule defines |
| The Foundation Performance Opinion | A finding | Things the rules require to be reported |
| Evidence of Water Penetration | A finding | Things the rules require to be reported |
| Evidence of Previous Repairs | A finding | Things the rules require to be reported |
| Conditions Not Required to Be Updated | A finding | Things the rules require to be reported |
| Recommend Further Evaluation | A gap in coverage | The inspector's own wording |
| Appears To Be | A qualifier | The inspector's own wording |
| At the Time of the Inspection | A qualifier | The inspector's own wording |
| Limited Visual Survey | A qualifier | The inspector's own wording |
| End of Useful Life | A qualifier | The inspector's own wording |