Inspection Report Reader logo — a house frame with a checkmark at its peakInspection Report ReaderWhat the words in a Texas inspection report mean
Line illustration of a violation placard fixed to a wall representing Deficient (D)
Box or defined termThe four boxesA finding

Deficient (D)

Deficient is the one box with a legal definition behind it. It covers everything from a missing cover plate to a failing roof, and it obligates no one to repair anything.

What the Deficient box tells you

The Deficient box, abbreviated D, records that the inspector reported one or more deficiencies in the item. It is the only box whose meaning rests on a two-part legal definition, and that definition is the key to reading every Texas report.

Under TREC rule 535.227, a deficiency is a condition that, in the reasonable judgment of the inspector, adversely and materially affects the performance of a system or component, or constitutes a hazard to life, limb or property as specified by the standards of practice. Deficient means reported as having one or more deficiencies.

So a D box can mean either of two different things:

The comment beside the box says which, and how much.

One box, a wide range of conditions

The same box covers conditions of very different weight. The standards of practice list, system by system, what the inspector must report as Deficient. A sample:

  • missing or damaged electrical cover plates, receptacles that are not tamper resistant below 5.5 feet, and GFCI devices that fail to operate;
  • deteriorated foundation materials, deficient foundation components and exposed or damaged reinforcement;
  • deficiencies in roof covering materials, fasteners, adhesion and flashing details;
  • attic ventilation that is not functioning, and missing insulation;
  • inoperative appliances and missing or damaged appliance components.

A report on a sound house can carry many D boxes, because so much of the list is small. A report on a house with a serious problem may carry only a few. Counting D boxes tells you little; reading the comments under them tells you a great deal.

What Deficient does not mean

It does not obligate repair. The form's preamble says, in capital letters, that items identified as Deficient do not obligate any party to make repairs or take other actions. What happens next is negotiated between buyer and seller under the contract.

It does not mean code violation. Texas inspectors are not required to determine code compliance, and the form states that the inspection is not a code-compliance inspection. A Deficient item may or may not break a code; a code issue may or may not be reported. The guide to code violations and the inspection report covers the difference.

It does not rank seriousness. The form says the inspector is not required to prioritize or emphasize the importance of one deficiency over another. Some inspectors add summaries or priority labels; those are the inspector's own additions, not part of the state's definition.

It does not identify the cause. The general limitations say the inspector is not required to determine the cause of a condition. TREC's published answers give a pointed example: an inspector may not say termites exist or caused damage, but should report visible damage as Deficient without assigning a cause, because wood-destroying insect inspections need a separate state license.

What is not reported as Deficient

The general limitations say the inspector is not required to report past repairs that appear effective and workmanlike, cosmetic conditions, or ordinary wear and tear. TREC's published answers add specific items not reported as Deficient, including the mere presence of corrugated stainless steel tubing (CSST) gas line, copper gas lines, transite pipe and a Federal Pacific Electric panel, and cosmetic corrosion on a fixture that operates. A report that is silent on such items is following the rule, not overlooking them.

Common mistakes with Deficient

Reading D as "fails". Many D items are minor corrections. The box is a flag to read the comment, not a verdict on the item.

Treating the D list as a repair list. Sending a seller every D item as a repair demand usually produces a negotiation about the few that matter. The guide to writing a repair request explains how the TREC amendment form expects specific repairs to be listed.

Assuming no D means no problem. An item can be uninspected (Not Inspected), inaccessible or concealed. Absence of a D box is not evidence of condition.

What to do with it

Read every D comment and sort them: hazards first, then items affecting major systems, then minor corrections. For anything you do not understand, ask the inspector. For anything that calls for a cost or a cause, follow the report's advice to obtain further evaluation from a qualified professional, and do it before the option period ends.

Where the rules come from

The definitions of deficiency and Deficient are in 22 TAC 535.227. The system-by-system lists are in 535.228 and 535.229 and the sections that follow. The statement that Deficient items obligate no one is in the preamble of form REI 7-6. TREC's answers on items not reported as Deficient are on its inspector questions page.

Frequently Asked Questions

Does Deficient mean the seller has to fix it?

No. The form states that items marked Deficient do not obligate any party to make repairs or take other actions. Repairs are a matter for negotiation under the contract.

Does Deficient mean the item violates building code?

Not necessarily. Texas inspectors do not determine code compliance, and the report is not a code inspection.

Why does my report have so many Deficient items?

The standards list many small conditions that must be reported as Deficient, such as missing cover plates. The number of D boxes says little; the comments say what matters.

Can an item be both Inspected and Deficient?

Yes. That is the normal way a defect appears: the item was inspected and one or more deficiencies were found.