The short answer
Since February 1, 2022, a licensed Texas inspector inspecting a substantially complete one-to-four family house for a buyer or seller has had to report on the Texas Real Estate Commission's Property Inspection Report Form, REI 7-6. The form has a fixed structure: identifying information, standard preamble pages, then six numbered sections from Structural Systems to Optional Systems, each item with four boxes and a comment area. Inspectors may add a cover page, summaries, photographs and attached pages, but the standard form must come first and its text must be reproduced exactly. Reading a report well means knowing which parts are the state's and which are the inspector's, and reading in an order that surfaces gaps and hazards before details.
How the form is organized
Identification. The first page names the client, the date, the property address, the inspector and the inspector's TREC license number, and any sponsoring inspector. TREC rule 535.222 requires the inspector's name and license number, the client's name and the property address on each page.
The preamble. Standard text explaining the purpose of the inspection, the inspector's and client's responsibilities, the report's limitations, and a notice about hazards in older houses. See the preamble pages.
The six sections. Structural Systems (foundations, grading and drainage, roof covering, roof structure and attic, walls, ceilings and floors, doors, windows, stairways, fireplaces and chimneys, porches and decks); Electrical Systems; Heating, Ventilation and Air Conditioning; Plumbing (including water heating and gas distribution); Appliances; and Optional Systems (such as irrigation, pools and spas, outbuildings, wells and private sewage systems), which the preamble says the inspector is not required to inspect; most inspectors cover them only by agreement.
Boxes and comments. Each item carries the boxes Inspected, Not Inspected, Not Present and Deficient, with a comment area for findings. See how the four boxes combine.
Additional information. Anything the inspector adds after the standard form, which may include photographs, summaries and contract terms. TREC does not regulate contract terms between inspector and client.
An order for reading
Read the preamble once. It is the same in every Texas report and sets the frame: a visual survey, one day, no obligation on anyone to repair, and further evaluation as the client's job.
List every gap. Find every NI box and every limitation or vantage-point statement. These are the parts of the house the report does not cover.
List every recommendation for further evaluation. These take longest to act on. See recommend further evaluation.
Find the hazards. Items reported as Deficient because they are a hazard to life, limb or property, including the older-house conditions the preamble lists.
Read the foundation opinion. Every Texas report must contain one. See the foundation performance opinion.
Read the rest of the Deficient items. Sort them into major systems and minor corrections.
Read the comments under items without a D. Required information such as evidence of water penetration and evidence of previous repairs is often reported without a Deficient box.
Look at the photographs with the comments. See photographs in an inspection report.
Words that change the meaning of a sentence
The comments mix findings, qualifiers and gaps. Phrases such as appears to be, at the time of the inspection and end of useful life limit what a finding claims. Defined words such as accessible, cosmetic and performance have meanings set by rule that differ from everyday usage. The glossary covers each.
Summaries are the inspector's, not the state's
Many reports open with a summary of key findings. The form does not require one, and the preamble says the inspector is not required to prioritize or emphasize one deficiency over another. A summary is the inspector's selection. Useful, but read the full report: gaps and required non-Deficient information rarely appear in summaries.
Guides in this section
The preamble pages walks through the standard opening text. How the four boxes combine explains each pairing of boxes. Photographs in an inspection report covers what a picture can and cannot establish.
Where the rules come from
The form is REI 7-6; its mandatory date is documented in TREC's 2021-2023 inspector course manual. Its required use and permitted changes are in 22 TAC 535.223; report contents and delivery in 22 TAC 535.222; and the standards of practice in 22 TAC 535.227-535.233. As of November 2026, TREC's inspector committee has sent proposed revisions to the standards and form to the Commission; see the committee's October 2026 report.