The short answer
TREC rule 535.227 sets out general limitations: a list of things a Texas inspector is not required to inspect, report, determine, anticipate or do. The system rules that follow add item-specific limits, such as crawl spaces under 18 inches of headroom and roofs that cannot be walked safely. The list is a floor for the service, not a ceiling: the scope says inspectors may go further if competent to do so. But a buyer should assume nothing on the list was done unless the report says it was.
Not required to inspect
The general limitations say the inspector is not required to inspect items other than those listed in the standards, and give examples of things outside scope, including:
- elevators, detached structures and other items not listed;
- items that are buried or concealed, and sub-surface drainage;
- automated control systems;
- concrete flatwork such as driveways, sidewalks and patios.
The system rules add more. The inspector need not enter a crawl space or area with less than 18 inches of headroom or an access opening smaller than 24 by 18 inches, or an attic with an opening smaller than 22 by 30 inches or headroom under 30 inches. The inspector need not inspect a roof from the roof level if it cannot be safely reached or walked, or if walking it may cause significant damage. See accessible and inaccessible.
Not required to report
The inspector is not required to report:
- past repairs that appear effective and workmanlike, unless the standards specifically require it;
- cosmetic or aesthetic conditions;
- wear and tear from ordinary use.
The roof standard is the notable exception on repairs: evidence of previous repairs to roof coverings, flashing, skylights and penetrations must be reported. See evidence of previous repairs.
Not required to determine
The inspector is not required to determine:
- the presence of pests or wood-destroying insects;
- the presence of mold, asbestos, lead-based paint, radon and other environmental hazards;
- the causes of conditions or deficiencies;
- insurability or warrantability;
- compliance with codes, regulations or manufacturer instructions;
- energy efficiency.
TREC's published answers add details: inspectors are not required to inspect to trade association standards, manufacturer requirements or local requirements except as the standards specify, and life expectancy is not determined. See code violations and the inspection report.
Not required to anticipate
The inspector is not required to anticipate future events or conditions, including decay, deterioration or damage after the inspection, the consequences of misuse, or future performance. That is why a report speaks at the time of the inspection, and why phrases such as end of useful life are judgments rather than predictions.
Not required to do
Among other things, the inspector is not required to:
- designate conditions as safe;
- operate shutoff valves or pressure-regulating valves;
- light pilot lights or turn on decommissioned equipment or utilities;
- move furnishings, stored items or appliances, or climb over obstacles;
- use specialized equipment or procedures, such as thermal imaging, moisture meters or destructive testing;
- review historical records or permits;
- provide repair estimates or re-inspections.
The REI 7-6 preamble repeats several of these, and adds that the inspector is not required to identify all potential hazards or prioritize one deficiency over another.
The departure provision
Separate from the list, the departure provision in rule 535.227(f) lets an inspector skip an item the standards do require, but only if the client agrees, the inspector is not qualified, conditions prevent inspection, conditions are hazardous to the inspector, or inspection may damage the property. The inspector must tell the client at the earliest practical opportunity and note the reason on the report. That is the source of most Not Inspected boxes.
Going beyond the minimum
The scope says the standards do not prohibit a higher level of inspection or inspection of additional components, provided the inspector has the competency to do so. Many inspectors offer additional services. A buyer who wants any of them should agree them in writing before the inspection and check that the report describes what was done.
Common mistakes
Assuming silence means clear. If an item is on the list, silence means it was outside the inspection.
Expecting the report to cover the driveway, the sewer line or termites. All are outside the standard inspection.
Treating the list as an excuse. It is the published definition of a service every licensed Texas inspector provides.
Where the rules come from