Inspection Report Reader logo — a house frame with a checkmark at its peakInspection Report ReaderWhat the words in a Texas inspection report mean
How to read the report

How the four boxes combine: reading Inspected, Not Inspected, Not Present and Deficient together

The four boxes on a Texas report are designed to be checked in combination. Each pairing says something different, and the rule requires the inspector to explain it.

The short answer

Beside every item on form REI 7-6 are four boxes: I (Inspected), NI (Not Inspected), NP (Not Present) and D (Deficient). TREC rule 535.223 requires the inspector to check the boxes that show whether each item was inspected, not inspected, not present or deficient, and to explain the findings in that item's comment area. It also requires that when more than one box is checked, the inspector explain why in that section. The combinations are deliberate. They let a single line say, for example, that an item was examined and found deficient, or partly examined, or skipped for a reason that is itself a defect.

The boxes on their own

Inspected. The item was examined within the standards of practice. It says nothing about condition. See Inspected.

Not Inspected. The item was present but not examined, and the reason must be stated. See Not Inspected.

Not Present. The house does not have the item. See Not Present.

Deficient. The item was reported as having one or more deficiencies under the rule's definition. See Deficient.

The combinations TREC describes

TREC publishes an instruction sheet for the form that explains how inspectors should check the boxes. It describes these pairings.

I and D. Both boxes should be checked any time a component or system is inspected and exhibits a deficiency. This is the ordinary way a defect appears in a Texas report. A buyer who reads I as "passed" will misread every one of these lines.

I and NI. Both boxes may be checked when a component or system is only partially inspected, and the inspector must explain which portions were inspected and which were not. Common examples are a roof walked on some slopes and viewed from the ground on others, an attic entered only near the hatch, or a plumbing system where some fixtures could not be run.

NI and D. Both boxes should be checked when a component or system is present but not inspected because of the inspector's judgment, and the reason it was not inspected meets the definition of a deficiency. The deficiency is the obstacle. A broken attic ladder that makes the attic unsafe to enter, or an electrical panel cover that cannot be safely removed, are the kind of conditions this pairing covers.

NP and NI. The instruction sheet also lists this pairing. As with every combination, the comment should explain it.

Reading a line with several boxes

Work through the boxes in order, then read the comment.

First, was the item examined (I), skipped (NI), absent (NP), or some mix? That tells you how much of the comment rests on observation.

Second, is D checked? If so, the comment should say what the deficiency is and where it is. TREC's course manual teaches that every statement of a deficiency has two parts, the deficiency and its location.

Third, is there a recommendation? A recommendation for further evaluation tells you the inspector's view of the next step.

Finally, does the explanation the rule requires actually explain the combination? If it does not, ask the inspector.

Why the combinations matter in a negotiation

Each pairing points to a different action.

An I and D line is a finding a buyer can put in front of a seller.

An I and NI line is a partial finding. The uninspected part is a gap the buyer may want filled before relying on the rest.

An NI and D line is both a finding and a gap: the obstacle is a deficiency, and what lies behind it is unknown.

An NI line alone is a gap with no finding.

A buyer sorting a report before writing a repair request should sort by combination, not only by section.

Common mistakes

Counting boxes. A report is not scored. TREC's course material lists value scales among the things inspectors should avoid.

Missing NI in a line that also says I. Partial inspections are easy to skim past.

Assuming NP means the inspector looked and found nothing wrong. It means the item is not there.

Ignoring the explanation. The rule requires one whenever more than one box is checked; its absence is worth a question.

Where the rules come from

The duty to check boxes and explain combinations is in 22 TAC 535.223(5). The combinations are described in TREC's REI 7-6 instruction sheet. The two-part statement and the advice against ratings are in TREC's 2023-2025 inspector course manual.

Frequently Asked Questions

Can an item be both Inspected and Deficient?

Yes. TREC's instruction sheet says both boxes should be checked any time an item is inspected and exhibits a deficiency.

What does it mean when Inspected and Not Inspected are both checked?

The item was only partly inspected. The inspector must explain which parts were and were not inspected.

How can something be Not Inspected and Deficient?

The item was not inspected because of a condition that itself meets the definition of a deficiency, such as an obstacle that makes inspection unsafe.

Does the inspector have to explain multiple boxes?

Yes. TREC's rule requires an explanation in the item's section whenever more than one box is checked.