Inspection Report Reader logo — a house frame with a checkmark at its peakInspection Report ReaderWhat the words in a Texas inspection report mean
Line illustration of a pressure gauge with an inspection tag hung from it representing Performance
Box or defined termWords the rule definesA qualifier

Performance

Performance is the yardstick behind most Deficient boxes. It is measured against accepted practice for a house of that age, not against new construction or the code.

What the word tells you

Performance is the first half of the Texas definition of a deficiency. A condition is a deficiency if, in the inspector's reasonable judgment, it adversely and materially affects the performance of a system or component. TREC rule 535.227 then defines performance as achievement of an operation, function or configuration relative to accepted industry standard practices, with consideration of age and normal wear and tear.

Three parts of that definition shape what a report means.

Operation, function or configuration. Performance covers whether something works (an air conditioner cools), whether it does its job (a gutter carries water away), and whether it is arranged properly (an electrical panel has the clearance in front of it that the standards require).

Relative to accepted industry standard practices. The yardstick is practice in the trade, not a building code edition and not a manufacturer's installation manual. TREC's published answers say inspectors are not required to inspect to trade association standards or manufacturer requirements except as the standards of practice specify, and that no general definition of "accepted industry practice" has been provided.

With consideration of age and normal wear and tear. A twenty-year-old system is judged as a twenty-year-old system. Wear that is normal for its age is not, by itself, a performance deficiency, and ordinary wear and tear is not required to be reported at all.

Adversely and materially

The definition of deficiency adds two qualifiers to performance: the effect must be adverse and material. A minor variation that does not meaningfully affect how the item works is not a deficiency. That threshold is the inspector's judgment, which is why two reports on similar houses can differ on borderline items.

How performance is tested

The general requirements say the inspector operates fixed or installed equipment in at least one mode, using ordinary controls at typical settings, and the definition of inspect refers to operating systems in normal ranges. That is a basic performance evaluation, as the scope of the standards describes the inspection: a limited visual survey and basic performance evaluation of the systems and components.

The limits matter. The inspector runs the air conditioning but does not measure refrigerant charge. The inspector runs the dishwasher through a cycle but does not test it under every setting. The scope says inspectors are not required to use specialized equipment or specialized procedures, and conditions on the day can prevent a test altogether. TREC's course manual gives the example of cooling not tested because the outdoor temperature was below 60 degrees.

The foundation is a special case

For foundations, the standards ask for more than a box: the inspector must render a written opinion on performance and report the visible indications used to form an opinion of adverse performance, such as binding doors, sloping floors and cracking. That has its own page: the foundation performance opinion.

What the word does not tell you

It does not tell you the item meets the current building code. Texas inspectors are not required to determine code compliance.

It does not tell you how long the item will continue to perform. The general limitations say the inspector is not required to anticipate future performance, and TREC's answers say life expectancy is not determined. See end of useful life.

It does not tell you that an item performing on the day will perform after purchase. TREC's answers say that a mechanical component failing after the inspection, such as a dishwasher, is not a basis for claiming the inspector should have predicted the failure.

Common mistakes

Expecting new-house standards in an older house. The definition builds age and wear into the yardstick.

Reading "performing" as "efficient". Energy efficiency is among the things the general limitations say the inspector is not required to determine.

Reading a passed basic test as a full test. One mode, ordinary controls, typical settings.

What to do with it

Where a performance finding concerns a major system, such as heating and cooling, plumbing or the roof, and the cost matters to your decision, have a licensed trade evaluate the system before the option period ends. A trade can run the tests the standards do not require, and give the cost estimates the form says the client should obtain.

Where the rules come from

The definitions of performance, deficiency and inspect, the general requirements and the general limitations are in 22 TAC 535.227 and on TREC's online standards of practice. TREC's answers on industry standards, manufacturer requirements and later failures are on its inspector questions page.

Frequently Asked Questions

What standard does a Texas inspector judge performance against?

Accepted industry standard practices, with consideration of the item's age and normal wear and tear. It is not a building code standard.

Does a passing performance check mean the system is efficient?

No. Determining energy efficiency is outside what Texas inspectors are required to do.

Why wasn't my air conditioner tested?

The standards allow an inspector to skip an item when conditions prevent it. TREC's course manual gives an outdoor temperature below 60 degrees as an example for cooling.

Is ordinary wear a deficiency?

Not by itself. Inspectors are not required to report ordinary wear and tear, and age and wear are built into the performance definition.