Box or defined termWords the rule definesA finding

A Hazard to Life, Limb or Property

An item can work perfectly and still be Deficient, because the second half of the Texas definition is about danger, not function.

What the phrase tells you

The phrase a hazard to life, limb or property is the second half of the Texas definition of a deficiency. Under TREC rule 535.227, a deficiency is a condition that, in the inspector's reasonable judgment, either adversely and materially affects the performance of a system or component, or constitutes a hazard to life, limb or property as specified by the standards of practice.

The second half matters because it reaches conditions the first half cannot. A receptacle without ground-fault protection beside a bathroom sink works perfectly. A range with combustible material stored within thirty inches above its burners cooks perfectly. Both are reported as Deficient, not because they fail, but because the standards treat them as hazards.

When a report marks an item Deficient and the comment describes something that seems to work, this is usually why.

How the standards specify hazards

The words "as specified by these standards of practice" tie the hazard test to the system rules that follow. Those rules list, item by item, what must be reported as Deficient, and many entries are hazards rather than performance failures. Examples from the electrical and appliance rules:

  • missing GFCI protection in the locations TREC rule 535.229 lists, such as bathrooms, garages, outdoor receptacles, kitchen countertops, laundry areas and within six feet of a sink, shower or tub;
  • missing AFCI protection in the living areas the rule lists;
  • missing smoke alarms in each sleeping room, outside each sleeping area and on each story, and missing carbon monoxide alarms where fuel-fired appliances or an attached garage are present;
  • receptacles less than 5.5 feet above the floor that are not tamper resistant;
  • under TREC rule 535.232, combustible material within thirty inches above cooktop burners, and garage door operators with door locks or side ropes that have not been removed or disabled.

The form's preamble adds a list of hazards that may have met the rules when a house was built but are reported as Deficient today if present and posing a significant risk: malfunctioning, improperly installed or missing GFCI and AFCI devices, ordinary glass where safety glass is now expected, missing fire-safety features, excessive baluster spacing, improperly installed appliances, and lack of electrical bonding and grounding, including gas piping bonding. That list has its own page: conditions not required to be updated.

Where judgment comes in

Not every hazard is listed. TREC's published answers to inspector questions say that whether a condition is a hazard, and what standard to use in deciding, are left to the inspector's reasonable judgment. Two inspectors may therefore differ on an unlisted condition, while a listed one should appear in every report.

TREC's answers also show where the line has been drawn on several items. A keyed deadbolt on an exterior door is not Deficient unless it impedes emergency escape from a sleeping room. An egress window with a sill above 44 inches is not automatically Deficient; judgment applies. A garage door sensor mounted more than six inches above the floor is Deficient, because the specific rule overrides the general limitation.

What the phrase does not tell you

It is not a safety certificate for the rest of the house. The form's preamble says the inspector is not required to identify all potential hazards, and the general limitations say the inspector is not required to designate conditions as safe. A report that reports three hazards has not declared everything else safe.

It does not cover environmental hazards. The general limitations exclude determining the presence of mold, asbestos, lead-based paint, radon and other environmental hazards. Those need separate testing by people qualified to do it.

It does not rank urgency. The form says the inspector is not required to prioritize one deficiency over another. Some reports add a safety flag or a summary; that is the inspector's own addition.

Common mistakes

Dismissing a hazard because the item works. The point of the second half of the definition is that working is not the test.

Dismissing a hazard because the house is old. The preamble's list of older-house hazards exists precisely so that age is not an excuse for silence.

Assuming every hazard was found. The inspection is a limited visual survey; concealed and inaccessible hazards are outside it.

What to do with it

Treat hazards as the first group when you sort a report. Most hazards the standards list are electrical or fire-safety items that a licensed electrician or the appropriate trade can assess and correct. Raise them early in the option period, because a seller's willingness to correct a hazard is part of the negotiation, and the form leaves the decision to correct to the parties to the contract.

Where the rules come from

The definition of deficiency is in 22 TAC 535.227. The electrical hazards are in 22 TAC 535.229, and the appliance items in 22 TAC 535.232. The older-house list is in the preamble of form REI 7-6. TREC's answers on judgment and specific items are on its inspector questions page.

Frequently Asked Questions

Why is something marked Deficient when it works fine?

Because a deficiency can be a hazard to life, limb or property as the standards specify, not only a performance problem. Missing GFCI protection is the common example.

Does the report list every hazard in the house?

No. The form says the inspector is not required to identify all potential hazards, and environmental hazards such as mold and asbestos are outside the inspection.

Who decides whether an unlisted condition is a hazard?

The inspector, using reasonable judgment. TREC leaves that decision to the inspector.

Does the seller have to fix reported hazards?

Not because of the report. The form leaves the decision to correct any hazard to the parties to the contract.